Explosion proof gas sensor/transmitter

Explosion proof gas sensor/transmitter
Производитель: RKI Instruments
Модель: S-series
Запросить цену
Описание

Features:

  • Explosion proof housing
  • Patented water repellent sensor coating
  • Operates independent of a controller
  • Available for LEL, H2S, CO, O2, and ppm HC
  • IR sensors available for LEL & CO2
  • H2 Specific LEL version available
  • Long life sensors (2 + years typical)
  • Competitively priced
  • UL or CSA approved

Applications:

  • Petrochemical Plants
  • Refineries
  • Gas Plants
  • Offshore Drilling Platforms
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • Chemical storage buildings

The RKI S series gas sensor/transmitters are highly reliable and cost effective basic 4-20 mA transmitters for the detection of common gas hazards. The S series transmitters are available for LEL (catalytic), LEL (IR) CH4, LEL (IR) HC, O2, H2S, CO, or CO2 (IR). The electronics are encased inside a potted package to avoid damage from mechanical abuse or corrosion, and this assembly is installed inside an explosion-proof enclosure. All sensors are explosion-proof with flame arrestors and approved for use in hazardous atmospheres. There is also an optional version for oxygen for use in non-hazardous atmospheres.
The only tools required to calibrate the S series are a voltmeter, screwdriver, and cal gas. The zero and calibration functions are performed by adjusting potentiometers on the amplifiers. The amplifier has test jacks for connecting to a voltmeter for calibration purposes, and the sensor response is viewed on the voltmeter as a 100 mV to 500 mV signal. Field calibration can be performed easily and quickly by one person.
The S series transmitters can be used either indoors or outdoors. The flame arrestors utilize a patented coating which make them water repellent, and splash guards are also available for use in very wet environments.
The transmitter operates from 24 VDC (11VDC to 30 VDC), and provides a 4-20mA signal which can be connected to a wide variety of controllers.

 

LEL

O2

H2S

CO

Infrared

CO2

CH4

HC

Part #

65-2400RK
65-2400RK-05

65-2513RK
65-2516RK
65-2504RK‘

65-2422RK-05

65-2432RK-05

65-2391RK-03

65-2390RK-CH4

65-2390RK-HC

Measuring Range

0-100% LEL

0-25% Vol.

0-100 ppm

0-300 ppm

0-5% Vol.

0-100% LEL

Max Current Draw

200 mA (power wires) 25 mA (signal wires) 3 wires

25 mA
(2 wire system)

60 mA
(power wires)
25 mA (signal wires) 3 wires

Outputs

4 - 20 mA signal

Response Time

30 seconds to 90% of concentration

20 seconds to 90% of concentration

45 seconds to 90% of concentration

30 seconds to 90% of concentration

Operating Environment

Location

Indoor/outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.

Indoor/outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D. (65-2516RK)

Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.

Temperature

-40 to 185° F

-4 to 113° F

-4 to 122° F

Humidity

0 - 99% RH, non condensing

Housing

Aluminum explosion proof enclosure

Sensors

Type

Catalytic
Combustion

Galvanic Cell

Electrochemical

Infrared

Life
Expectancy

1 to 2 years with normal intermittent exposure to flammable gas

2 years normal service

2 years normal service when intermittently exposed to H2S

2 to 3 years normal service

5 + years normal service

Controls

Zero

Sets transmitter output to 4 mA with 0% LEL output from combustible sensor

Sets transmitter output to 4 mA with an inert gas (zero)
output from O2 sensor

Sets transmitter output to 4 mA with zero output from H2S sensor

Sets transmitter output to 4 mA with zero output from CO sensor

Sets transmitter output to 4 mA with zero output from CO2 sensor

Sets transmitter output to 4 mA with 0% LEL output from combustible sensor

Span

Sets transmitter output to 20 mA with 100% LEL output from combustible sensor

Sets transmitter output to 17.44 mA with 20.9% Vol. O2 (fresh air) output from O2 sensor

Sets transmitter output to 20 mA with 100 ppm output from H2S sensor

Sets transmitter output to 20 mA with 300 ppm output from CO sensor

Sets transmitter output to 20 mA with 5% volume output from CO2 sensor

Sets transmitter output to 20 mA with 100% LEL output from combustible sensor

Operating
Voltage

11 VDC to 30 VDC

Approvals

65-2400RK UL 65-2400RK-05 C CSA US

65-2516RK C CSA us

C CSA us

C UL US

Warranty

One year materials and workmanship